Tanklevel
Tank level meter | |
---|---|
Status | Stable
|
menuconfig | Applications->Tank level meter |
Pinning | yes |
Ecmd | yes |
Depends on | ECMD, Clock, ADC, Cron (optional) |
Code | https://github.com/ethersex/ethersex/tree/master/services/tanklevel |
Tanklevel provides an application for measurement of tank levels by hydrostatic pressure.
Internals
You need an aquarium air pump, some kind of pipe/tube, a Freescale MPX5050DP pressure sensor and an relay for the pump. Parameters are configurable by ECMD and stored in EEPROM.
Mechanical setup
+-------+ |Sensor | +---+---+ | +--------+ +---------------+-+ Pump | | +--------+ +------+------+ | | | | | | |------|------| | | | | | | | | | +-------------+ Tank
Electrical setup
Electrical Setup is quite simple. Connect the TANK_PUMP port with an relay (usually via an Transistor as current amp) and the output of the Sensor with the selected ADC channel (have a look at the datasheet for power supply decoupling and output filtering). Select a optimal Vref for the ADC if possible.